TUTORIAL: how to acces / enter hidden (secret) menu on VW Golf Mk5, Jetta in 3 steps
If you want to find out what VW Golf Mk5 climatronic menu is hiding, you have to follow this 3 simple steps from the video below.
See more Cool Products for VW Golf Mk5, Jetta at the Best Price HERE:
HJere is a video tutorial on how to enter hidden (secret) menu on VW Golf Mk5, Jetta in 3 simple steps:
Before you start the engine, make sure that the gear shift is in the neutral position.
STEP 1: turn ignition on
STEP 2: turn the air conditioner on pushing the OFF button
STEP 3: press on the ECON button or AC (on other models) and the up-arrow button in the same time
To navigate through hidden menu use only the first two switches. On the left screen will be displayed a specific channel and on the right side the required values.To return to the original menu , press the ECON button (or AC on other models).
Below there’s a list of all the channels of the climatronic hidden meniu:
System Data Type
0 – 0 Program number Digital
0 – 1 ERL Left Digital
0 – 2 ERL Right Digital
0 – 3 Point being used Digital
0 – 4 Recirculating Automatic Digital
0 – 5 Stationary Heating Active Digital
0 – 6 Air Quality (7 = Fresh Air) Digital
0 – 7 Derived Digital
0 – 8 Country Acronym Digital
0 – 9 Sensor Zone Head °C
1. UIF
1 – 0 Internal Temperature °C
1 – 1 External Temperature °C
1-2 Temperature, Platelets, In, Platinum ° C
1-3 Corrector, Platelets, In, Platinum ° C
1-4 FIU – Sonnenint, Digital
1-5 Sun Intensity Corrected ° C
1-6 Corrector , Dynamic ° C
1-7 Corrector, recirculation ° C
1-8 concealer, Heat ° C
1-9 Compensation ignition UIF ° C
- Sun Intensity Sensor Left
2 – 0 Sun Intensity Not Corrected W/m2
2 – 1 Sun Intensity Corrected W/m2
2 – 2 Fan Correction W/m2
2 – 3 Value Digital3. Sun Intensity Sensor Right
3 – 0 Sun Intensity Not Corrected W/m2
3 – 1 Sun Intensity Corrected W/m2
3 – 2 Fan Correction W/m2
3 – 3 Value Digital4 . External Temperature
4 – 0 Temperature External °C
4 – 1 Temperature External CANBUS °C
4 – 2 Temperature Intake °C5. Temperature Left Setpoint
5 – 0 Temperature Output °C
5 – 1 Difference between temp and temp setpoint °C
5 – 2 Regulator Setting (½%)
5 – 3 Pi-Stell-Max? (½%)
5 – 4 Defrost Digital6. Temperature Left Actual
6 – 0 Temperature °C
6 – 1 Footwell °C
6 – 2 Vents °C7. Temperature Right Setpoint
7 – 0 Temperature Output °C
7 – 1 Difference between temp and temp setpoint °C
7 – 2 Regulator Setting (½%)
7 – 3 Pi-Stell-Max? (½%)
7 – 4 Defrost Digital8. Temperature Right Actual
8 – 0 Temperature °C
8 – 1 Footwell °C
8 – 2 Vents °C9. Evaporator Temperature Setpoint
9 – 0 Evaporator temperature °C
9 – 1 Difference between temp actual and temp Setpoint °C
9 – 2 Evaporator value settings 5mA/Dig
9 – 3 Sensor Sight10. Evaporator Temperature Actual
10 – 0 Evaporator Temperature °C
10 – 1 Liquid refigerant pressure bar
10 – 2 Liquid refigerant temperature °C11. AC Compressor
11 – 0 Power setpoint mA
11 – 1 Power actual mA
11 – 2 Power maximum mA
11 – 3 Compressor PWM Digital (0-200)
11 – 4 Power offset compressor
11 – 5 Power value Digital
11 – 6 Compressor code12. Climate Control Fan
12 – 0 Fan Setpoint Voltage V
12 – 1 Manual regulation
12 – 2 Code anomaly
12 – 3 Reduction impeller V
12 – 4 Impeller offset 0.1V13. Temperature Air Vent Left
13 – 0 Setpoint value %
13 – 1 Setpoint temperature Digital
13 – 2 Actual Temperature Digital
13 – 3 Maximum Temperature Digital
13 – 4 Minimum Temperature Digital14. Temperature Air Vent Right
14 – 0 Setpoint value %
14 – 1 Setpoint temperature Digital
14 – 2 Actual Temperature Digital
14 – 3 Maximum Temperature Digital
14 – 4 Minimum Temperature Digital15. Temperature Air Vent Diffuser
15 – 0 Setpoint value %
15 – 1 Setpoint temperature Digital
15 – 2 Actual Temperature Digital
15 – 3 Maximum Temperature Digital
15 – 4 Minimum Temperature Digital16. Temperature Air Vent Defrost
16 – 0 Setpoint Value %
16 – 1 Setpoint temperature Digital
16 – 2 Actual Temperature Digital
16 – 3 Maximum Temperature Digital
16 – 4 Minimum Temperature Digital17. Temperature Internal Recirculation
17 – 0 Setpoint Value %
17 – 1 Setpoint temperature Digital
17 – 2 Actual Temperature Digital
17 – 3 Maximum Temperature Digital
17 – 4 Minimum Temperature Digital18. Temperature External Air
18 – 0 Setpoint Value %
18 – 1 Setpoint temperature Digital
18 – 2 Actual Temperature Digital
18 – 3 Maximum Temperature Digital
18 – 4 Minimum Temperature Digital19. Engine Data
19 – 0 Vehicle Speed (kph) kph
19 – 1 Vehicle Speed (mph) mph
19 – 2 Engine Temperature °C
19 – 3 Engine speed RPM
19 – 4 AC compress speed RPM20. CANBUS Data
20 – 0 Additional Heating 1=on
20 – 1 PTC Confirmation 1=on
20 – 2 Effective Power PTC A
20 – 3 Air requested from external %
20 – 4 External air percentage cooler %
20 – 5 Performance heating 1=no external provision21. Air Distribution
21 – 0 Defrost %
21 – 1 Face %
21 – 2 Feet %
21 – 3 Air Vent Diffuser %
21 – 4 Recirculated %
21 – 5 Air Sensor %22. Time
22 – 0 Engine Off Time minutes
22 – 1 Engine Operating Time seconds
22 – 2 Operating Time with Ignition On seconds23. Special. Channel
23 – 0 Inner Lighting Sensor Digital
23 – 1 Air Quality Sensor24. Software Version
24 – 0 Development State
24 – 1 Software Version
24 – 2 Type of Software
24 – 3 Keep Frozen 0/1 – Diagnosis
24 – 4 Version K Matrix
24 – 5 EEP – Testflags
24 – 6 Encryption Vag (2)25. Test Channels
25 – 0 Channel 0
25 – 1 Channel 1
25 – 2 Channel 2
25 – 3 Channel 3
25 – 4 Channel 4
25 – 5 Channel 5
25 – 6 Channel 6
25 – 7 Channel 7
25 – 8 Channel 8
25 – 9 Channel 926. Parameters for inventory on crystals
26 – 0 Delay seconds
26 – 1 Step/udm? (Digital) Digital
26 – 2 Minimal Limit (Digital) Digital
26 – 3 Maximum Limit (Digital) Digital
26 – 4 Step/udm? HellaKit? 1=connected27. Direct Ventalation
27 – 0 Setpoint Value %
27 – 1 Setpoint temperature Digital
27 – 2 Actual Temperature Digital
27 – 3 Maximum Temperature Digital
27 – 4 Minimum Temperature Digital28. Humdity
28 – 0 Setpoint Humdity %
28 – 1 Relative Humdity %
28 – 2 Temperatur Crystal WSS °C
28 – 3 Dewpoint temperature °C
28 – 4 Melting point °C29. Raw Humdity
29 – 0 Tempertaure crystals corrected °C
29 – 1 Tempertaure crystals uncorrected °C
29 – 2 Humdity Sensor %
29 – 3 Temperature sensor °C
29 – 4 Dewpoint temperature (measurement test) °C
29 – 5 Code anomaly30. Humdity Values
30 – 0 Thermophilic sensor value Digital
30 – 1 Thermophilic sensor reference Digital
30 – 2 Moisture duration 10 to the power of -4 sec
30 – 3 Humdity reference temperature Digital
30 – 4 Humdity sensor %
30 – 5 Temperature sensor °C
30 – 6 Temperature sensor (uncorrected) °C
HERE you can find LED Indicator Lights and Brake Turn Signal Lights for you car:
HERE you can find All-Included Pre-Built Bundles HELIOS is 100% plug and play on almost every car:
Get the best car wax sprays, ceramic coatings and DIY car detailing products – manufactured in the USA, at a fraction of the price:
Everyone at Wurzel Performance prides themselves in the quality of the products and services they provide:
This video is only for informative purposes! We do not take any responsibility and we are not liable for any damage as a result of the information contained in this video. Use this information at your own risk. Thank you!
Check these VIDEO TUTORIALS for VW, Audi, Skoda, Seat:
How to change MFA cluster display language for VW Audi Skoda Seat!
How to activate the indicators on as DRLs (day time running lights)!
How to replace VW, Seat, Audi, Skoda key fob in 11 steps!
How to acces hidden / secret menu in 3 steps!
How to replace headlight bulb in 6 simple steps!
Does it work on an Passat B5.5?